Title: Comparison of dynamic contour tonometry (Pascal®) with pneumotonometry and Goldmann tonometry
Other Titles: Comparación del tonómetro Pascal® con el neumotonómetro y el tonómetro Goldmann
Author(s) : Heras-Mulero, H. (H.)
Moreno-Montañes, J. (Javier)
Sadaba-Echarri, L.M. (Luis M.)
Mendiluce, L. (Loreto)
Issue Date: 2007
Publisher: Elsevier España
Citation: Heras-Mulero H, Moreno-Montanes J, Sadaba Echarri LM, Mendiluce Martin L. Comparison of dynamic contour tonometry (Pascal) with pneumotonometry and Goldmann tonometry. Arch Soc Esp Oftalmol 2007 Jun;82(6):337-341
Keywords: Tonometry, Ocular/instrumentation
Ppneumotonometry
Abstract: To compare the intraocular pressure measurements as defined by the Pascal tonometer, the Goldmann tonometer and the pneumotonometer. METHODS: This was an observational clinical study, which included two hundred and five randomly selected subjects recruited from the Ophthalmology Department. The intraocular pressure measurements were performed with each tonometry technique in a randomized order. RESULTS: The Pascal's intraocular pressure measurement was significantly higher than that measured by the other two tonometers (p<0.05). The quality data of Pascal was: optimum in 27.3% (56 of 205 patients), acceptable in 42% (86 of 205 patients) and unacceptable in 23.4% (48 of 205 patients). In 7.3% (15 of 205 patients) it was impossible to obtain any measurement using Pascal. A weak correlation coefficient between the Pascal and the Goldmann, and between Pascal and the pneumotonometer was found. The Bland-Altman method of measurement using these tonometers showed a high degree of discordance. CONCLUSION: As reported by others authors, the Pascal's intraocular pressure measurement is higher than that of the Goldmann tonometer. The measurement differs from 0.7 to 4.4 mmHg. In corneas with pathology, it is very difficult or even unacceptable to measure the intraocular pressure using the Pascal tonometer.
URI: http://hdl.handle.net/10171/23331
Publisher version (URL): http://www.oftalmo.com/seo/archivos/maquetas/A/7CC3A6F7-11D6-7E88-AB90-000065858ACA/articulo.pdf
Appears in Collections:DA - CUN - Oftalmología - Artículos de revista

Files in This Item:

File Description SizeFormat
articulo-1.pdf195,19 kBAdobe PDFView/Open
Statistics

Import into RefWorks

SFX Query

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2010  Duraspace - Feedback