The role of angled-tip microcatheter and microsphere injection velocity in liver radioembolization: A computational particle–hemodynamics study.
Keywords: 
Angled-tip microcatheter.
Computational fluid-particle dynamics.
Hemodynamics.
Hepatic artery.
Radioembolization.
Issue Date: 
Dec-2017
Publisher: 
Wiley
ISSN: 
2040-7939
Citation: 
Aramburu, J., Anton, R., Rivas, A., Ramos, J. C., Sangro, B., & Bilbao, J. I. (2017). The role of angled‐tip microcatheter and microsphere injection velocity in liver radioembolization: A computational particle–hemodynamics study. International Journal for Numerical Methods in Biomedical Engineering, 33(12), e2895.
Abstract
Liver radioembolization is a promising treatment option for combating liver tumors. It is performed by placing a microcatheter in the hepatic artery and administering radiation-emitting microspheres through the arterial bloodstream so that they get lodged in the tumoral bed. In avoiding nontarget radiation, the standard practice is to conduct a pretreatment, in which the microcatheter location and injection velocity are decided. However, between pretreatment and actual treatment, some of the parameters that influence the particle distribution in the liver can vary, resulting in radiation-induced complications. The present study aims to analyze the influence of a commercially available microcatheter with an angled tip and particle injection velocity in terms of segment-to-segment particle distribution. Specifically, 4 tip orientations and 2 injection velocities are combined to yield a set of 8 numerical simulations of the particle-hemodynamics in a patient-specific truncated hepatic artery. For each simulation, 4 cardiac pulses are simulated. Particles are injected during the first cycle, and the remaining pulses enable the majority of the injected particles to exit the computational domain. Results indicate that, in terms of injection velocity, particles are more spread out in the cross-sectional lumen areas as the injection velocity increases. The tip's orientation also plays a role because it influences the near-tip hemodynamics, therefore altering the particle travel through the hepatic artery. However, results suggest that particle distribution tries to match the blood flow split, therefore particle injection velocity and microcatheter tip orientation playing a minor role in segment-to-segment particle distribution.

Files in This Item:
File
The role of angled‐tip microcatheter and microsphere injection velocity in liver radioembolization.pdf
Description
Size
2.12 MB
Format
Adobe PDF


Statistics and impact
0 citas en
0 citas en

Items in Dadun are protected by copyright, with all rights reserved, unless otherwise indicated.